Double Braid Hose

Specifications and Size Range

For Double Stainless Steel wire braid hose (DB Grade) and Antistatic (AS, DB) Grade.

Standard Wall, Double Braid (SW, DB)

Bore Size (Nominal)Bore Size
(Actual)
PTFE Tube Wall ThicknessBraid Outside DiameterMinimum Bend RadiusMaximum Working PressureWeight per Unit Length*Part Number
mminmminmminmminBarpsiKg/mtLbs/Ft
1/83.170.1250.760.0306.850.270207/83605238.100.06770-100-02-02-02
3/164.760.1880.760.0258.700.3433011/43304802.135.09170-100-03-02-02
1/46.350.2500.630.02510.050.3964015/82904220.160.10770-100-04-02-02
5/167.940.3130.630.02511.550.4555022503638.190.12770-100-05-02-02
3/89.530.3750.630.02513.350.5266023/82303347.214.14370-100-06-02-02
1/212.700.5000.760.03016.400.6469035/81802629.341.22970-100-08-02-02
5/815.880.6250.760.03019.950.78513051/81351964.416.27970-100-10-02-02
3/419.050.7500.760.03023.100.91017063/41001455.503.33770-100-12-02-02
125.401.0001.000.03929.601.165270103/4701019.700.46970-100-16-02-02

 

Heavy Wall, Double Braid (HW, DB)

Bore Size (Nominal)Bore Size
(Actual)
PTFE Tube Wall ThicknessBraid Outside DiameterMinimum Bend RadiusMaximum Working PressureWeight per Unit Length*Part Number
mminmminmminmminBarpsiKG/mtLbs/Ft
1/83.170.1251.000.0397.050.278183/43505093.108.07270-200-02-02-02
3/164.760.1881.000.0398.900.3502513204656.140.09470-200-03-02-02
1/46.350.2501.000.03910.750.4232611/83104511.183.12370-200-04-02-02
5/167.940.3131.000.03912.350.4863511/22754001.210.14170-200-05-02-02
3/89.530.3751.000.03914.100.5555022403492.243.16370-200-06-02-02
13/3210.320.4061.000.03915.050.5936023/82303347.258.17370-500-13-02-02
1/212.700.5001.000.03916.900.6657532002900.374.25170-200-08-02-02
5/815.880.6251.300.05120.750.81710041552255.452.30370-200-10-02-02
3/419.050.7501.300.05123.800.93713553/81101601.532.35670-200-12-02-02
125.401.0001.500.05930.701.20925097/8841222.730.48970-200-16-02-02
11/431.751.2501.500.05936.901.453400153/4751091.905.63770-200-20-02-02
11/238.101.5001.500.05943.751.722800311/2659461.170.78470-200-24-02-02
250.802.0001.500.05956.402.2211200471/4405821.6101.07970-200-32-02-02

 

Medium Wall, Double Braid (MW, DB) also referred to as Hyperline SB, DB

Bore Size (Nominal)
BB = Big Bore
Bore Size
(Actual)
Dash Size Reference (if any)PTFE Tube Wall ThicknessBraid Outside DiameterMinimum Bend RadiusMaximum Working PressureWeight per Unit Length*Part Number
mminmminmminmmimBarpsiKg/mtrLbs/Ft
1/16BB2.00.079-21.000.0406.000.236111/25407800.075.05070-300-02-02-02
1/8BB3.50.138-31.000.0407.450.293183/43505000.111.07470-300-03-02-02
3/16BB5.00.200-40.760.0308.800.3473513/83404900.128.08670-400-03-02-02
1/4BB6.70.264-50.760.03011.000.4335023204600.170.11470-400-04-02-02
5/16BB8.50.335-60.760.03011.820.4666023/82703900.215.14470-400-05-02-02
3/8BB10.00.394 0.760.03014.200.5608032303300.260.17470-400-06-02-02
1/2BB13.60.536-100.760.03017.350.68411043/81802600.350.23470-400-08-02-02
5/8BB16.60.654-120.840.03320.800.82014051/21301900.450.30070-400-10-02-02
3/4BB19.80.780 1.000.04024.000.94616061/21201700.520.35070-400-12-02-02
1 BB26.41.040 1.000.04031.701.24921081/41001400.830.55070-400-16-02-02

* For Anti-Static Grade, add 10 to the 3-digit part number e.g. 70-100 becomes 70-110. For High Pressure Gas Grade, add 20, eg 70-200- becomes 70-220.

Note: A few of the sizes of hose and fittings listed above are available as ex-stock items and are priced accordingly. However, most of the items are not stocked, and will therefore incur a minimum order charge or a set-up charge for small quantities.

Temperature & Pressure

  • Temperature affects the Maximum Working Pressure (MWP) as listed above, so for temperatures above 130˚C reduce the MWP by 0.75% for each 1˚C above 130˚C. Example: at 180˚C, reduce the MWP by (180 - 130) x 0.75 = 37.5%.
  • Pressure Ratings above 100 Bar (1500 psi) only apply for the transfer of non-penetrating fluids. If gases or penetrating fluids are used in the application, or used during pressure testing at pressures above 100 Bar, HPG grade hose is required.
  • Maximum Working Pressures (MWP) listed are calculated on the basis of a 3:1 safety factor relative to the burst pressure, so Burst Pressure = 3 x MWP. If MWP is required based on a 4:1 safety factor (e.g EN 16643 requirement), multiply the listed value by 0.75.